Absolute measuring probe S_Probe P12D
12.7mm / USB, M8, Open / 0.1µm or 0.01µm
Brand: SYLVAC (swiss made)
--------------------------------------------
Description
- High-precision measuring probes with patented measuring system combining inductive and capacitive technologies
- Absolute system with integrated electronic error correction (no more pairing with the unit or computer)guaranteeing high accuracy over the entire measuring range
- Extremely robust ball bearing guide guarantees a minimum of 100 million cycles (30 millions with radial load)
- Stainless steel body Ø 12 mm, fixing diameter 8 h6
- Measuring range 12.7 mm
- Available in 3 versions: Standard, Work and Pro
- Measuring force selectable: low or very low for vertical use only
- Output signal in direct digital format without the need for a converter
- Reading speed up to 100 values per second depending on configuration
- Straight cable length 2m with either USB or M8 connector
- Cable outlet protected by a spring which can be tilted by 90° with the optional accessory 801-5101
- Protection class IP54
Absolute measuring probe S_Probe P12D
12.7mm / USB, M8, Open / 0.1µm or 0.01µm
Brand: SYLVAC (swiss made)
----------------------
Technical Specifications
PRO | 801-1012 | 801-1018 | 801-1212 | 801-1218 |
Resolution type | High resolution |
Type | P12D HR USB | P12D HR USB CF | P12D HR M8 | P12D HR M8 CF |
Force | 0.2 - 0.3 N | 0.08 N | 0.2 - 0.3 N | 0.08 N |
Measuring range | 12.7 mm |
Resolution | 0.01 µm |
Max. Error | 0.6 µm |
Repeatability | 0.08 µm |
Nb measures/s | up to 100/s, according to configuration |
Output data | USB | M8 |
Cable output | Straight |
STANDARD | 801-2012 | 801-2017 | 801-2212 |
Resolution type | Standard |
Type | P12D USB | P12D USB LF | P12D M8 |
Force | 0.4 - 0.8 N | 0.2 - 0.3 N | 0.4 - 0.8 N |
Measuring range | 12.7 mm |
Resolution | 0.1 µm |
Max. Error | 1 µm |
Repeatability | 0.2 µm |
Nb measures/s | up to 100/s, according to configuration |
Output data | USB | M8 |
Cable output | Straight |
WORK | 801-0212 | 801-0012 |
Resolution type | Standard |
Type | P12D WORK M8 | P12D WORK USB |
Force | 0.4 - 0.8 N |
Measuring range | 12.7 mm |
Resolution | 0.1 µm |
Max. Error | 1.8 µm |
Repeatability | 0.2 µm |
Nb measures/s | up to 100/s, according to configuration |
Output data | M8 | USB |
Cable output | Straight |
OPEN | 801-0412 |
Resolution type | Standard |
Type | P12D OPEN |
Force | 0.4 - 0.8 N |
Measuring range | 12.7 mm |
Resolution | 0.1 µm |
Max. Error | 1.8 µm |
Repeatability | 0.2 |
Nb measures/s | up to 100/s, according to configuration |
Output data | OPEN |
Cable output | Straight |